The water resistant facade boards STIROCOKL, expanded in a mould, used for the insulation of the socle - the foundation of the facade above the level of the underground parts in ETICS facade systems in accordance with ETAG 004, for insulation of reveals, edges of reinforced concrete plates, lintels, balconies and closing of cornices. A grid on both sides gives better grip of the adhesive. Boards are installed with facade adhesives or by additional mechanical attachment. During installation we must follow the installation instructions and applicable professional and legal regulations.
CHARACTERISTICS
standard SIST EN 13163
reaction to fire E after EN 13501-1 resp. B1 after DIN 4102
expanded in tool (mould)
on both sides is a ribbed grid of 1 × 1 cm for better grip of adhesive and basic plaster
for thermal insulation of edges of reinforced concrete slabs, window falls and balconies
for insulations of facade socles over underground parts
thermal conductivity λD= 0,037 W/(m.K)
DIMENSIONS
thickness of boards: 2 cm - 25 cm
size of boards: 100 × 50 cm
unit of measure: m2
PACKAGING
packages in PE-film: approx. 0,25 m3
pallet: approx. 5 m3