Sustainability Report
Embodied carbon
Documented strategies with potential embodied-carbon benefits include:
- The building uses a relatively restrained material palette, including cream-city brick and board-and-batten cladding.
- Value engineering was undertaken in response to construction-cost increases, requiring the design team to reassess the building while retaining the geothermal and solar systems identified as sustainability priorities.
- The building's long-term flexibility can reduce the likelihood of major future alterations as program requirements change.
- Future expansion capacity was considered in the building and site planning, including the photovoltaic infrastructure.
Operational Emissions / Energy
Actual energy benchmarking has been conducted following occupancy rather than relying solely on predicted performance.
Measured operational energy:
The 2025 HGA benchmarking reported:
25 kBtu/ft²/year without solar PV.
17 kBtu/ft²/year with solar PV.
Solar generation offset approximately 34% of the building load. For the 31,257 ft² building, 17 kBtu/ft²/year corresponds to approximately 155,700 kWh/year of energy use. Using the reported 34% solar offset, approximately 102,800 kWh/year would remain supplied by the grid.
Using an EPA eGRID RFC West electricity factor of approximately 413.3 kg CO₂/MWh, this corresponds to an estimated 42,500 kg CO₂/year, or approximately 14.6 kg CO₂/m²/year of location-based operational electricity emissions after the reported solar contribution.
The project has a comparatively well-documented operational-energy strategy:
- 42-well geothermal bore field for heating and cooling.
- Electric heat pumps rather than fossil-fuel combustion equipment.
- No natural-gas connection, resulting in zero on-site combustion emissions.
- 129 photovoltaic panels / 61.92 kWdc of installed solar capacity.
- Efficient windows and lighting.
- Extensive daylight access through strategically oriented glazing.
- Water-conserving plumbing fixtures.
- Future capacity for additional photovoltaic generation.
Service and maintenance emissions
Several design decisions can reduce future operational and maintenance requirements:
- The geothermal system replaces conventional fossil-fuel heating equipment and associated fuel infrastructure.
- The all-electric approach simplifies the building's energy supply by eliminating natural-gas infrastructure.
- The brick base and exterior cladding provide durable enclosure materials.
- The open and flexible floor plan allows spaces to change function without requiring extensive reconstruction.
- The photovoltaic system was designed with additional capacity for future expansion, reducing the need to redesign the basic solar infrastructure when generation is increased.
- Energy benchmarking during the first year of operation provides a mechanism for identifying operational adjustments and improving system performance over time.
Afterlife
Adaptive reuse was not the primary strategy because the project is a new-build library replacing an undersized downtown facility, but some measures support flexibility:
- Meeting rooms can potentially be converted into office areas and vice versa.
- The open second-floor arrangement supports changing library functions.
- The children's collection and program room can be combined through a sliding glass door.
- The site and building were planned to accommodate future expansion.
- The photovoltaic system has structural and inverter capacity for additional solar panels.