Sustainability Report

Embodied carbon

Efficient
600
kg CO₂-eq./m²
5
kg CO₂-eq./m²

The calculation is based on standard emission factors from international LCA databases (such as ICE Database and One Click LCA benchmarks), adapted to the project’s material palette.

 

  • Steel structure contributes the largest share of embodied carbon (~250–300 kg CO₂-eq./m²).

  • Cement render has a medium footprint (~100–120 kg CO₂-eq./m²).

  • Aluminum façade elements are energy-intensive in production but designed for potential reuse, accounting for ~150–180 kg CO₂-eq./m².
    All primary building components (structure, envelope, finishes) are included. Mechanical/electrical installations and interior furnishings are not included in this assessment.

Operational Emissions / Energy

Low Carbon
40
kg CO₂e/m²


This estimate is based on benchmark data from similar mid-rise buildings with double-skin façades in cold-to-temperate climates. The double-skin façade significantly reduces heating demand by creating a thermal buffer, while natural ventilation strategies cut down on cooling loads.
Key design choices that reduced operational emissions include:

 

  • Double-skin façade with aluminum outer layer, acting as a thermal buffer to minimize heating demand.

  • Optimized window-to-wall ratio, balancing daylight and heat loss.

  • Natural ventilation potential through façade cavities, reducing reliance on mechanical cooling.

  • Efficient HVAC integration tailored to the climate of Tabriz.

Service and maintenance emissions

Low Carbon
5
kg CO₂e/m²
  • Double-skin façade

    • The aluminum second skin has high durability (20–25 years lifespan before major replacement).

    • Requires periodic cleaning, but minimal material replacement.

    • Aluminum is recyclable, which reduces long-term maintenance emissions.

  • Cement façade (inner layer)

    • Needs repainting/repairs approximately every 15–20 years.

    • Maintenance emissions are moderate because cement surfaces do not demand frequent replacement.

  • Metal structure

    • Long life span with minimal intervention.

    • Protective coatings/anti-corrosion treatments may add small recurring emissions.

 

  • Mechanical/Electrical systems

    • HVAC and lighting systems will need replacement (every 15–20 years).

    • This is the main contributor to maintenance emissions.

Afterlife

 

Adaptive Reuse:
Yes — the project was designed with adaptive reuse potential in mind. The steel structural system provides large spans and open floor plates, allowing the building to be reconfigured for different uses over time. While it currently serves its original program, the flexible structural grid and modular façade system would allow it to be adapted into alternative uses such as cultural, educational, or mixed-use functions without major structural alterations.

 

Flexible Floorplan:
The interior layout relies on column-beam steel frames with minimal load-bearing walls, which enables easy re-partitioning of spaces. This makes the plan inherently flexible and suitable for future reprogramming.

 

Yes — several building elements were intentionally designed in a way that they can be disassembled and reintroduced into the circular economy:

  • Aluminum façade panels → lightweight, modular, and fully detachable. They can be removed without damaging the main structure and are 100% recyclable.

  • Steel structural system → bolted connections instead of fully welded joints in many parts allow sections of the frame to be dismantled and reused, or fully recycled as secondary steel.

  • Secondary façade elements (shading devices, fixings, LED modules) → designed in modular units, enabling component-level replacement and reuse.

  • Cement-based finishes → though less directly reusable, they can be crushed and recycled as aggregate for future concrete production.

 

Overall, the double-skin system acts as a circular design feature: it protects the inner layer and ensures that external components (aluminum modules, shading devices, glazing) can be maintained, replaced, or recycled without compromising the primary structure.