The Tederic International Center is located in Qiantang District, Hangzhou, within the Hangzhou Economic and Technological Development Zone. The project consolidates office, hotel, commercial, and manufacturing functions into a single campus, supporting the ongoing transformation of China’s manufacturing sector toward higher-value, technology-driven production.
Developed for Tederic, a publicly listed manufacturer of injection moulding and die-casting machines with operations globally, the project establishes a centralized base for research, production, and corporate activities. The campus spans 33,335 square meters, with a total built-up area of 75,117 square meters, comprising three primary buildings and a smart factory.
Material innovations
Several building components replace conventional steel and concrete systems with lightweight alternatives, including polycarbonate panels and aluminum–magnesium alloy assemblies. This approach reduces structural loads while improving construction efficiency.
The facade is designed as a double-layer curtain wall system, combining Low-E laminated glazing with an external expanded aluminum mesh. The outer mesh layer provides solar shading while maintaining approximately 70 percent light transmittance, reducing glare, and limiting solar heat gain.
Polycarbonate panels are used across both roof and facade applications. These panels incorporate recycled content derived from post-consumer waste and include co-extruded UV protection layers to maintain light transmission and material stability over time. The glazing strategy was developed through iterative testing, with more than twelve configurations evaluated to balance daylight penetration and solar control across different orientations. The final system adapts glazing types to facade exposure, supporting consistent environmental performance across the campus.
Campus and spatial strategy
The project integrates manufacturing and public-facing functions within a continuous campus framework. Office, commercial, and hospitality programs are organized alongside the factory, enabling operational efficiency while introducing a degree of permeability between typically separated industrial and urban environments.
Envelope and architectural system
The architectural language is defined by a modular, prefabricated curtain wall system composed of aluminum profiles. The unitized facade improves construction efficiency and reduces on-site waste while supporting consistent envelope performance.
Operable window panels are incorporated within the facade to support natural ventilation in office areas, improving indoor air quality and reducing reliance on mechanical systems. The industrial-focused economic development zone is described as dim at night. Centred on the concept of "City Lamp," the design introduces warm lighting, turning the factory buildings into visible elements within the area's nighttime environment and illuminating routes through the site.
The design introduces a distinct expressive approach for industrial buildings and explores the aesthetic and functional potential of polycarbonate panels. It establishes a clear identity for the factory within its urban context.
Architectural language
The high-tech design approach reinforces the identity of both the technology innovation community and the client’s manufacturing profile. Clean lines form a simple silhouette, emphasizing standardized geometric units and the use of modern materials, creating a sense of lightness and order. The double-layered curtain walls and outward-protruding wings produce a layered effect through the interplay between solid and void, enhancing visual depth and a sense of movement.
The curtain wall is a significant component of a building's thermal performance, accounting for approximately 40 percent of overall energy consumption, and is therefore important in achieving energy efficiency. The double-layer curtain wall system is based on a prefabricated aluminum profile unit, reducing construction time and improving efficiency.
Shadow layer
After a comparative study of perforated panels, woven mesh, and expanded aluminum mesh, the more cost-effective expanded aluminum mesh was selected as the shading layer. This material maintains light transmission while reducing surface reflectivity, minimizing glare and improving visual comfort. Its structure also promotes air circulation, supporting the building's environmental performance.
The combination of reflective backing panels and glass conceals fire protection systems and structural components within the shadow box, creating a layered effect. This approach maintains transparency and visual consistency across the facade.
In addition, operable windows were integrated within the building’s wings to support natural ventilation and indoor comfort. By altering the traditional window-opening mechanism, each full-height glass panel provides an increased clear width, allowing wider views while maintaining functionality.
Smart factory
The factory is organized around a triangular roof truss system with optimized connection joints, reducing steel consumption by approximately 20 percent. The structure integrates daylighting and environmental control strategies within its assembly.
The roof combines polycarbonate panels with aluminium–magnesium–manganese corrugated sheets and interlocking components, balancing structural stability with thermal performance. The translucent polycarbonate elements allow daylight to penetrate deep into the production spaces, reducing reliance on artificial lighting.
Prefabricated components and customized connection systems were developed through simulation and testing to improve assembly precision, durability, and resistance to environmental stress.
Sustainability overview
Building orientation was informed by sunlight analysis so that the main facades maximize daylight penetration and reduce artificial lighting demand.
The factory uses a double-layer ventilated roof that enables natural convective airflow: warm air rises through the upper layer while cooler air is drawn upward from below, providing passive ventilation for production spaces. Office areas incorporate operable openings to support cross-ventilation and indoor air quality.
The campus integrates a three-level landscape system consisting of green roofs, ground-level planting, and a sunken garden plaza. The sunken garden introduces daylight and air into underground parking areas while reducing heat accumulation at ground level. Rainwater collected from the roof is treated and reused for non-potable purposes within the campus.