Ten kilometres northeast of the heart of Vienna, Baumschlager Eberle Architekten has completed Robin Seestadt: three mixed-use buildings that maintain interior temperatures of between 22 and 26 degrees celsius without mechanical systems. Completed in 2024 on the last undeveloped plot in Seeparkquartier, the project offers a location-specific take on passive design principles.
2226 Principle
The 2226 principle—named for its target temperature band—was developed by Baumschlager Eberle and first built in 2013 as the practice’s own headquarters in Vorarlberg. The central idea is that a building can maintain this range year round without conventional HVAC systems by employing a range of passive strategies: high mass walls that absorb and slowly release heat, carefully calculated window-to-wall rations that control solar gain, ventilation to flush heat or cold air, and the 2226 Operating System software to control energy flows. Heat is provided by occupants and appliances; cooling is controlled by the software.
Materials
Robin Seestadt is the principle’s first large-scale application by an external developer: three five-storey buildings totalling 10,500 square metres, commissioned by SORAVIA for a mix of office tenants and Schloss Seeburg private university. The structural logic underpinning the building’s climate performance is Wienerberger brick construction and lime render finish. The walls function simultaneously as load-bearing structure, thermal insulation and heat store. Window-to-wall ratios are carefully controlled to balance daylight against solar gain and the spacing and orientation of openings respond to prevailing conditions on each facade.
Software
The 2226 Operating System — software developed by 2226 GmbH — mediates between the passive architectural envelope and the interior environment. Sensors monitor carbon levels and temperature across each floor, triggering the integrated ventilation panels. In summer, the panels open at night to flush the warm interior with cooler outside air; in winter, they modulate to prevent excessive heat loss while maintaining air quality. The system is designed to make incremental adjustments rather than large corrective interventions that characterise conventional HVAC systems. On the rare occasions when a Vienna summer produces sustained heat beyond what the passive strategy can absorb, a ceiling cooling circuit—powered entirely by the complex's rooftop photovoltaic installation—provides a climate-neutral failsafe.
Sustainability certification
The removal of mechanical infrastructure for heating and cooling reduces construction costs, eliminates maintenance cycles, and extends the functional life of the building fabric — a logic that is confirmed by the ÖGNB Gold certification all three buildings have received.